This Affinity Chromatography Column is made of high-purity polypropylene with a very low adsorption to various biomolecules. Frits for AC column are made of UHWMPE, which is hydrophilic, and optimized for minimizing non-specific adsorption.
• Minimizing non-specific adsorption.
• Excellent hydrophilic performance.
• Can be used for substances of low concentration.
• Rapid separation is achieved while avoiding contamination.
| 產品編號 | 品名 | 規格 | 包裝 |
|---|---|---|---|
| HY-K0221.1 | 親和層析管柱 | 1 mL | 10個/包 |
| HY-K0221.3 | 親和層析管柱 | 3 mL | 10個/包 |
| HY-K0221.6 | 親和層析管柱 | 6 mL | 10個/包 |
| HY-K0221.12 | 親和層析管柱 | 12 mL | 10個/包 |
| HY-K0221.30 | 親和層析管柱 | 30 mL | 5個/包 |
| HY-K0221.60 | 親和層析管柱 | 60 mL | 5個/包 |
Q1:HY-K0221 管柱是如何支撐 resin?需要另外加濾棉嗎?
A:
HY-K0221 親和層析管柱內部已內建篩板(screen / frit)作為 resin 的支撐與阻擋結構,
產品本身不含濾棉,且一般情況下不需要額外加裝濾棉,即可正常使用。
Q2:篩板孔徑是否會造成 resin 流失?
A:
HY-K0221 管柱所使用之篩板孔徑約為 50 µm,
可以有效攔阻絕大多數 resin 粒徑,因此:
不會造成 resin 流失
可穩定支撐 resin,適合此粒徑範圍的親和層析應用
Q3:1 mL、3 mL、6 mL 管柱的內徑(ID)是多少?
A:
Q4:在僅使用篩板、假設resin 粒徑為 130 µm 的情況下,有操作建議嗎?
A:
在上述條件下,可依一般親和層析標準流程正常操作:
無需額外加裝濾棉
無特殊流速或裝填限制
建議依實驗室既有操作條件使用即可
(補充說明)
HY-K0221 系列管柱:有篩板、無濾棉
適用於常見親和層析 resin 與重組蛋白純化應用
裝柱:
取適量樹脂與純化填料,放至層析空柱中(填料裝載於上下篩板之間)。
操作:
層析柱裝填完成後,請依所使用之純化填料,參考相關操作流程進行純化操作。
步驟可參考下圖